Since their introduction in 2004, CarbonCast High Performance Insulated Wall Panels and their components have undergone a three dozen third-party tests to verify their durability, insulating performance, composite action and more. The tests include:
- Behavior of a 42-Foot CarbonCast EPS-Insulated Composite Wall Panel (North Carolina State University)
- Age Effect on the Interface Bond of Expanded Polystyrene (EPS) and Concrete for Precast Concrete Sandwich Wall Panels (North Carolina State University)
- Direct Tensile Strength of Precast Concrete Sandwich Reinforced with CFRP Grid (North Carolina State University)
- Evaluation of the Effect of Sustained Loading on C-GRID/Rigid Foam Insulation Shear Transfer Mechanism in Precast Concrete Sandwich Panels
- CarbonCast Panels Tested in Accordance with ICC-ES AC422 (North Carolina State University)
- Shear Transfer Mechanism of Concrete Sandwich Panels Connected by Neopor Foam and CFRP Grid (North Carolina State University)
- ASTM E119-00a Fire Tests of Building Construction and Materials (Omega Point Laboratories)
- NFPA 285 Testing of a Concrete Wall Panel Assembly with XPS (InterTek)